Alert Types.
- (AB) Adaptor Board Not Found When an Adaptor Board not Found (AB) alert occurs, it means that a 72 or 96 station controller is not Alert Types
- (ALK) Advanced Leak When an advanced leak alert occurs, flow has exceeded both the advanced leak alert threshold and the evaluation time threshold Alert Types
- (CCRP) Climate Center Rain Pause When a Climate Center Rain Pause (WeatherTRAK Rain Pause) alert occurs, it means that irrigation has been paused by the Alert Types
- (CLK) Catastrophic Leak When a catastrophic leak alert occurs, flow has exceeded the catastrophic leak and evaluation time thresholds during non-irrigation hours. Possible Alert Types
- (CM) NO ET Communication A No ET Communication Alert is a communication alert that occurs when ET data (Evapotranspiration) has not been received for Alert Types
- (CO) Controller Off When a Controller Off (CO) status alert occurs, it means that a user has placed the controller into OFF mode. Alert Types
- (CP) Controller Paused When a controller paused alert occurs, it means that irrigation has been paused by either a rain pause or rain Alert Types
- (DY) Water Day Possible Cause: Current weather conditions require run times that exceed the lengths of the water window. Possible Fixes: * Change the Alert Types
- (EP) User Event Pause When a user event pause alert occurs, it means that irrigation has been configured to pause for an event. All Alert Types
- (EX) Extended Leak When an extended leak occurs, flow has exceeded the leak detect threshold continuously for the extended leak period during non-irrigation Alert Types
- (FLO) Flow Key Missing When a flow key missing alert occurs, it means that the flow key permission key is not being recognized on Alert Types
- (HF) Station High Flow When a station high flow alert occurs, flow has exceeded the station high flow threshold, which is set during the Alert Types
- (HW) Hardware A hardware alert occurs when the controller is not detecting all of the user-defined Max Active Stations. Irrigation will not Alert Types
- (LF) Station Low Flow When a station low flow alert occurs, the station’s flow rate is below the station low flow threshold. The Alert Types
- (LK) Leak A Leak alert occurs when the flow has exceeded the Leak Detect Threshold for the first leak delay period. Possible Alert Types
- (MB) Mainline Break If a mainline break has occurred, flow has exceeded the mainline break threshold and the controller will close the station Alert Types
- (MBlk) Mainline Break Leak When a mainline break leak alert occurs, flow has exceeded the mainline break threshold when irrigation is off. Possible Causes Alert Types
- (MDAC) Master Valve Decoder Address Conflict A Master Valve Decoder Address Conflict happens when the controller recognizes multiple master valve decoders assigned to a single master Alert Types
- (MDNF) Master Valve Decoder not Found A Master Valve Decoder not Found alert happens when the controller cannot communicate with the master valve decoder on the Alert Types
- (MHF) Manager High Flow When a manager high flow alert occurs, flow has exceeded the station high flow threshold. Possible Causes * A broken sprinkler Alert Types
- (MI) Manual Irrigation When a manual irrigation status alert occurs, it means that a user has started manual irrigation on a single or Alert Types
- (MLF) Manager Station Low Flow A Manager Station Low Flow alert occurs when the total combined value of all active stations drops below the Station Alert Types
- (MNF) Manager No Flow A Manager No Flow alert occurs when flow has dropped below the No Flow threshold for that mainline. An alert Alert Types
- (MVF) Master Valve Fault When a master valve fault alert occurs, the master valve is closed, but flow is being detected above the alert Alert Types
- (MVO) Master Valve Override When an MV Override (MVO) status alert occurs, it means that the controller’s irrigation is being paused by a Alert Types
- (NC) No Connect Valve alerts are viewed in the Alerts menu. If you have an alert, you will see a two-letter abbreviation (NC, Alert Types
- (NF) No Flow Alert A no flow alert means that the flow has dropped below the No Flow Threshold. Possible Causes: * The solenoid plunger Alert Types
- (OC) Over-Current When a valve over-current alert occurs, the current draw for a single valve solenoid has exceeded the station electrical threshold. Alert Types
- (OFI) OptiFlow Inspector When an OptiFlow Inspector alert occurs, it means that the OptiFlow Inspector tool has detected a programming issue that can Alert Types
- (OFL) Controller Offline When a controller offline alert occurs, it means that the controller has not had recent communication with the WeatherTRAK Central Alert Types
- (PK) Permission Key An OptiFlow permission key resembles a USB thumb drive and is located on the back of the control panel. The Alert Types
- (POC) Point of Connection not Found When a Point of Connection Not Found alert occurs, it means that a program has been assigned to a mainline Alert Types
- (PSM) Pump Start Missing When a Pump Start Missing (PSM) alert occurs, it means that a station identified as the pump start is not Alert Types
- (RS) Rain Switch On When a Rain Switch On alert occurs, the controller has been placed in a rain pause due to a rain Alert Types
- (SB) ET Subscription An ET Subscription Alert is an account alert, indicating that the ET Everywhere subscription has expired. An ET Subscription Alert Alert Types
- (SBK) Station Break Note This type of alert applies to OptiFlow controller only. When a station break alert occurs, the mainline break threshold Alert Types
- (SD) System Shutdown When a system shutdown alert occurs, it means that a user has turned off all irrigation by placing the controller Alert Types
- (SDAC) Station Decoder Address Conflict A Station Decoder Address Conflict happens when multiple station decoders are assigned to a specific station number. When the Station Alert Types
- (SDNF) Station Decoder Not Found When a Station Decoder Not Found alert occurs it means that the controller is not communicating with the station decoder Alert Types
- (SE) SE Irrigation ON When a SE Irrigation ON (SE) alert occurs, it means that the controller is operating stations that are scheduled for Alert Types
- (SH) Valve Short When a short alert occurs, the current draw for a single valve solenoid has exceeded 3.0 amps. When shorts Alert Types
- (SHD) Station High Depletion When a station high depletion alert occurs, it means that the station depletion rate is greater than 70% while in Alert Types
- (SNF) Stations Not Found When a stations not found alert occurs, the controller is not detecting all of the user-defined max active stations. The Alert Types
- (SOC) System Over Current When a system over current alert occurs, it means that the current electrical draw for a group of stations has Alert Types
- (TBM) Terminal Board Mismatch Note This alert is for the ET Pro3 and OptiFlow XR controllers, firmware versions 6.6 or 7.2+ or Alert Types
- (UKM) Update Key Missing A cloud update key resembles a USB thumb drive and is located on the back of the control panel. The Alert Types
- (URP) User Rain Pause When a user rain pause alert occurs, it means that irrigation has been paused by a user because of rain. Alert Types
- (UU) Unexpected Usage Info An unexpected usage alert is for the OptiFlow controller only. This alert happens when an OptiFlow controller measures usage Alert Types
- (W) Winterized When a winterized alert occurs, it means that the controller has been placed into a winterized status. All scheduled irrigation Alert Types
- (WD) Water Window When a water window alert occurs, there is a conflict between a program and a water window. This usually occurs Alert Types