Moisture Sensor: Two-Wire Communication Error

Updated May 5, 2026 1 min read

Moisture Sensor Two-Wire Communication Error

This is when the controller is receiving the error: Two-Wire Communication Error Unable to talk to this Device

This can be a constant issue or an intermittent issue.

Troubleshooting

Constant Communication Error

  • Dig up the Moisture Sensor
    • Make sure its clean and dry
  • Take it to the controller
  • Make sure the Controller is Powered down
  • Disconnect the Field wiring from the controller
  • Connect the Moisture sensor to the Two-Wire Terminals 
  • Power the controller on
  • If the Moisture Sensor is NOT new
    • Self Test
    • Test single Two-Wire Device
    • See if we get a response
  • If the Moisture Sensor IS new
    • Assign
    • Moisture Sensor
    • Search for the Moisture Sensor
    • See if the Sensor can be located by the controller

If the Moisture Sensor responds without a Two-Wire Communication or a Two-Wire Error then the Sensor is fine.

If the Moisture Sensor is unable to communicate with the controller please refer to the RMA Article

Troubleshooting

Intermittent Two-Wire Communication Errors

  • Confirm Sensor functions without errors at the controller
  • Dig up the Moisture Sensor
    • Make sure its clean and dry
  • Take it to the controller
  • Make sure the Controller is Powered down
  • Disconnect the Field wiring from the controller
  • Connect the Moisture sensor to the Two-Wire Terminals 
  • Power the controller on
  • If the Moisture Sensor is NOT new
    • Self Test
    • Test single Two-Wire Device
    • See if we get a response
  • If the Moisture Sensor IS new
    • Assign
    • Moisture Sensor
    • Search for the Moisture Sensor
    • See if the Sensor can be located by the controller

If the Moisture Sensor responds its a field issue.

If the Moisture Sensor does not respond please refer to the RMA article.

Most common Field issues:

  • Corrosion
  • bad splices
  • nicked wiring

All field issues are the clients responsibility to resolve and you can only suggest possible issues and direct to the Moisture Sensor Installation Instructions. 

Was this article helpful?