Master Valve Override (MVO) Matrix

Updated January 26, 2026 2 min read

A Master Valve Override (MVO) can be started in three places:

  1. On weathertrak.net, go to the Smart Irrigation tab and go to Controller List page. Select the controller you want to send an MVO to, click on the Advanced drop-down in the top right-hand corner, select <Scheduled Task - MV Override>, fill out as desired, and send.
  2. On weathertrak.net, mouse over the Smart Irrigation tab and click on Manage Controller. Go to the controller you want to send an MVO to. Click on <Edit> next to "MV Override" at the top, fill out the dates and times, and send.
  3. On the controller, press Manual Test and the +/- buttons until you reach the Manual : 07 screen. (For 8.x controllers, the controller must be unlocked/placed in Maintenance Mode beforehand.)

Under Optiflow > Configure or Smart Irrigation > Program > Setup, you should see settings for your mainlines.

  • If your POC is configured so that Master Valve Override is included, all master valves will be included in the MVO.
  • If your POC is configured so that Master Valve Override is excluded, that master valve will be left out of the MVO.

If an MVO is scheduled, it can be found under Rain Pause on the controller. Navigate to the Pause : 03 screen using the +/- buttons and you should see something like "T2          MV-Override" and its status (Active, Expired, etc.) underneath.

During an MVO:

  • Controllers with a Normally Closed (NC) Master Valve will display the Master Valves included in the override on the Run screen (ex. MV1) next to MVO.
  • Controllers with a Normally Open (NO) Master Valve will display MVO.
  • Controllers with a Normally Open (NO) Master Valve and a Mainline Break alert will display the NO Master Valve(s) on the screen (ex. MV1) and, in 7.8+/8.4+, prevent the MVO.
Action
Expected Behavior: 6.8
Expected Behavior: 7.x
Expected Behavior: 8.x
Start MVO during scheduled irrigation Scheduled irrigation stops for duration of MVO Scheduled irrigation stops for duration of MVO Scheduled irrigation continues during MVO
Start MVO during a Mainline Break alert MVO is not allowed

7.7.3: MVO is allowed

7.8+: MVO is not allowed

8.3.3: MVO is allowed

8.4+: MVO is not allowed

Start MVO and receive a Mainline Break alert in the middle of MVO MVO is not allowed

7.7.3: MVO continues during Mainline Break alert

7.8+: MVO is not allowed

MVO is not allowed

Start MVO before manual irrigation (MI) MI and MVO should overlap MI and MVO should overlap MI and MVO should overlap
Start MVO during MI MI and MVO should overlap MI and MVO should overlap MI and MVO should overlap
Start MVO while controller is in Off mode MVO is allowed

MVO is allowed

MVO is allowed

Start MVO while controller is in Winterized mode MVO is not allowed MVO is allowed MVO is allowed
Start MVO while controller is in Shutdown mode MVO is not allowed MVO is allowed MVO is allowed