A no flow alert means that the flow has dropped below the No Flow Threshold.


Possible Causes:

  • The solenoid plunger is not lifting to allow the valve to open
  • The master valve is not opening if in use
  • The pump start is not being activated
  • A gate valve or isolation valve in the mainline has been closed

When this type of alert occurs, the controller will stop irrigation on the station and raise a No Flow alert. It will then move onto the next station in the scheduled sequence. If three consecutive stations have No Flow alerts, the controller stops irrigation.



Possible Fixes:

  • Bleed the corresponding valve manually to determine if water pressure exists
  • Verify the Pump Start is operating correctly
  • Locate and open any closed gate valves


Clearing a No Flow alert from the controller:

1.  Press ALERTS.

2.  Press à. The VIEW FLOW STATUS screen displays.

3.  Press * to clear flow alert.


Clearing a No Flow Alert from WeatherTRAK Central:

1.  Hover over the Alerts tab and click Alert List. A list of all active alerts will display.

2.  Place a checkmark next to the alert you would like to clear.

3.  Press the Clear Flow and Electrical Alerts button. A pop-up screen displays asking you to verify the change. Click Yes.