(POC) Point of Connection not Found

Lance Elliott Updated March 21, 2026 1 min read


When a Point of Connection Not Found alert occurs, it means that a program has been assigned to a mainline which does not have a configured Point of Connection (POC). When this type of alert occurs, the controller cannot get flow information or control a master valve for the program. 

The controller will still run stations normally.


Possible Causes:

  • The master valve is set to normally open or normally closed, but the master valve is not found.

  • A flow sensor is selected, but the flow sensor is not found.

  • The pump start is assigned to a station, but that station is not found.


Possible Solutions:

  • Configure and assign the appropriate POC to the mainline.

  • Change the program to a mainline with a configured POC.

To learn more about flow and configuring POC’s, read: Selecting Flow Options for Learning

 


Clearing a Point of Connection Not Found (POC) Alert:

This alert must be cleared by fixing the configuration issue.