Lance Elliott Updated April 6, 2026 1 min read

A hardware alert occurs when the controller is not detecting all of the user-defined Max Active Stations. Irrigation will not occur on those stations, because the controller cannot irrigate stations that are not detected.


Possible causes

  • The user-defined Max Active Stations exceeds the number of stations detected by the controller

  • One or more Station Keys are missing or improperly installed

  • The ribbon cable between station input/output boards is defective or connecting pins are bent

  • A station output board has been damaged


To View a Hardware Alert

1.  Press ALERTS.

2.  Press  until the VIEW HARDWARE STATUS screen displays.

3.  Press SELECT to view the alert.


Possible Fixes

  • Verify Max Active Stations in SETUP menu

  • Confirm ribbon cables are seated properly

  • Verify the number of Station Keys is adequate for the required stations

  • Use another ribbon cable or unbend the connector pins

  • Look for scorch marks on the board or a strong odor of burnt components. Replace as needed.


How to Clear a Hardware Alert

Approximately 30 seconds after the situation is remedied, the controller automatically clears this alert.