- "Flow Fault" in BaseStation 1000 How to tell if Flow Fault Message: Quick View will not have an error or message, but if you go Video
- BaseManager Connect Error Info, impact, causes, and troubleshooting a BaseManager Connect Error message. Common Causes * Local area network (LAN) being down. * Network has Video
- BaseManager Connect Error Alert BaseManager Connect Error Priority: Medium Definition: When the controller is unable to connect to the BaseManager Server Example: This occurs Messages & Alerts
- Clock Failure Message At the 1000, Substation & FlowStation, troubleshoot by: 1. Disconnect from BaseManager 2. Set the time 3. Make sure the Video
- Controller Boot Up Alert Controller Boot Up Priority: Medium Definition: The controller has been reset either due to a power failure or a controller Messages & Alerts
- Controller Date Stop Step-by-Step Guide Understanding the Alert The Controller Event Date Stop message indicates that all watering has been stopped for the Video
- Controller Flow Stop Jumper Message Step-by-Step Guide Understanding the Flow Stop Jumper Message The Controller Flow Stop Jumper message indicates that the controller has detected Video
- Controller Off Step-by-Step Guide Understanding the Controller Off Message The Controller Off message indicates that the controller dial has been physically turned Video
- Controller Rain Days Stop Controller Rain Days Stop Priority: Low Definition: The controller was put in a rain pause Example: This is when someone Messages & Alerts
- Controller Rain Stop Jumper Message Overview The Controller Rain Stop Jumper message indicates that the controller has detected an open rain sensor contact and has Video
- Controller Restore Successful Message Overview The Controller Restore Successful message confirms that your controller's backup file has been successfully restored. This message Video
- Device Disabled Step-by-Step Guide Understanding the Device Disabled Message When a device is disabled in your system, you will receive a message Video
- Device Moisture Sensor Bad Reading Alert Device Moisture Sensor Bad Reading Priority: High Definition: The Controller is unable to get a valid moisture reading from the Messages & Alerts
- Device Pressure Bad Reading Device Pressure Bad Reading Priority: High Definition: The controller is unable to communicate to the pressure sensor Example: This is Messages & Alerts
- Device Two Wire No Response Info, impact, causes, and troubleshooting a "Device Two Wire No Response" message. Common Causes * Damaged or corroded wire Video
- Device Valve Decoder Open Circuit Info, impact, causes, and troubleshooting a "Device Valve Decoder Open Circuit" message. Common Causes * A failure solenoid or Video
- Device Valve Decoder Short Circuit Info, impact, causes, and troubleshooting a "Device Valve Decoder Short Circuit" message. Common causes * Issue related to the Video
- Device Wrong Serial Number Alert Device Wrong Serial Number Priority: Medium Definition: When the serial assigned to the device is the incorrect serial number Example: Messages & Alerts
- Flow Contacts Triggered Message Step-by-Step Guide Wiring Options for PFS-200 Flow Sensors on Conventional Wire Controllers When installing a PFS-200 (plastic flow sensor, two-inch) Video
- Flow Variance & Limits Dan answers a question out of Boston on flow limits and flow variance. Here's the alert subscriptions process: Video
- FlowStation Connect Error Info, impact, causes, and troubleshooting a "FlowStation Connect Error" message. Common Causes * Loss of power to the FlowStation. Video
- Mainline Disabled Alert Mainline Disabled Priority: None Definition: A Mainline was disabled Example: This occurs when a Mainline has been disabled; thus anything Messages & Alerts
- Mainline High Flow Variance Detected Step-by-Step Guide Understanding the Message The Mainline High Flow Variance Detected message indicates that the controller measured a higher flow Video
- Mainline High Flow Variance Shutdown Info, impact, causes, and troubleshooting a "Mainline High Flow Variance Shutdown" message. Common Causes * Broken mainline pipe. * Zone Video
- Mainline Low Flow Variance Detected Step-by-Step Guide Understanding the Message The Mainline Low Flow Variance Detected message indicates that the controller detected a flow rate Video
- Mainline Low Flow Variance Shutdown Info, impact, causes, and troubleshooting a "Mainline Low Flow Variance Shutdown" message. Common Causes * Flow restriction on the Video
- POC Disabled Alert POC Disabled Priority: None Definition: The Point of Connection (POC) has been disabled. Example: This occurs when the Point of Messages & Alerts
- POC High Flow Detected Alert POC High Flow Detected Priority: High Definition: The measure flow exceeded the limit that was set in the Control Point Messages & Alerts
- POC High Flow Shutdown Info, impact, causes, and troubleshooting a "POC High Flow Shutdown" message. Common Causes * Break on Mainline. * Flow limit Video
- POC High Pressure Shutdown Step-by-Step Guide When a POC high pressure shutdown occurs, the message displays the following information: POC High Pressure Shutdown with Video
- POC Unscheduled Flow Detected Message Step-by-Step Guide Understanding the Message The POC Unscheduled Flow Detected message indicates that the controller measured flow through a flow Video
- POC Unscheduled Flow Shutdown Step-by-Step Guide When a POC unscheduled flow shutdown occurs, the message displays the following information: POC Unscheduled Flow Shutdown with Video
- Program Learn Flow Complete Errors Info, impact, causes, and troubleshooting a Program Learn Flow Complete Errors message. Common Causes * Issue could be zone-specific. * Issues could Video
- Program Learn Flow Complete Success Alert Program Learn Flow Complete Success Priority: Low Definition: This alert is stating that the controller was able to complete the Messages & Alerts
- Program Over Run Step-by-Step Guide A program overrun message indicates that a program was still running when its next scheduled start time arrived. Video
- Program Pause Water Window Step-by-Step Guide The Program Pause Water Window message indicates that a program has been paused because a water window is Video
- Program Paused Event Switch Message Step-by-Step Guide Understanding the Program Paused Event Switch Message When a program paused event switch is triggered, you will receive Video
- Program Paused Moisture Alert Program Paused Moisture Priority: Low Definition: The Moisture sensor pause condition limit has been met and this program is paused Messages & Alerts
- Program Paused Pressure Message Step-by-Step Guide Understanding the Program Paused Pressure Message The Program Paused Pressure message appears when a pressure sensor detects that Video
- Program Priority Preempt Step-by-Step Guide Understanding the Program Priority Preempted Message When you receive a Program Priority Preempted message, it indicates that a Video
- Program Skipped Moisture Info, impact, causes, and troubleshooting a "Program Skipped Moisture" message. Common Causes * Sensor SB16822 being set to influence Video
- Program Stopped Pressure Alert Program Stopped Pressure Priority: Low Definition: The pressure limit set in the program has been reached and so the program Messages & Alerts
- SubStation Connect Error Info, impact, causes, and troubleshooting a "SubStation Connect Error" message. Common Causes * No power to the SubStation. * A Video
- SubStation Connect Error Alert SubStation Connect Error Priority: High Definition: The 3200 is unable to connect to the substation Example: Action Needed: Alert and Messages & Alerts
- Two-Wire Overcurrent Roberto had a two-wire over current issue in his field wiring, here's Dan's response. Here' Video
- Water Source Budget Exceeded Info, impact, causes, and troubleshooting a Water Source Budget Exceeded message. Common Causes * Water budget being enabled for conservation purposes. Video
- Water Source Budget Exceeded Alert Water Source Budget Exceeded Priority: Low Definition: This alert appears when the monthly budget that is set in the Water Messages & Alerts
- Water Source Budget Exceeded Shutdown Info, impact, causes, and troubleshooting a "Water Source Budget Exceeded Shutdown" message. Common Causes * Water budget enabled as Video
- Water Source Empty Event Switch Info, impact, causes, and troubleshooting a Water Source Empty Event Switch message. Event Switches (also known as Event biCoders) allow Video
- Water Source Empty Pressure Sensor Step-by-Step Guide Understanding the Alert Message The Water Source Empty Pressure Sensor alert indicates that a cistern or tank has Video
- Zone Shutdown High Flow Variance Info, impact, causes, and troubleshooting a "Zone Shutdown High Flow Variance" message. Common Causes * Broken or missing sprinkler Video
- Zone Shutdown Low Flow Variance Info, impact, causes, and troubleshooting a "Zone Shutdown Low Flow Variance" message. Common Causes * Plugged sprinkler heads on. Video